CanogaOS Configuration Guide
Proprietary & Confidential Canoga Perkins Metro Ethernet Switches Page 86 of 350
Figure 1
Bridge1
DUT# configure terminal Enter the Configure mode.
DUT(config)# vlan database Enter the VLAN database..
DUT(config vlan)# vlan 30 Configure VLAN 30
DUT(config vlan)# exit Exit the VLAN database
DUT(config)# ethernet cfm domain customer level 5 Create a domain,
DUT (config-ether-cfm)#service cst vlan 30 Define a Maintenance Association
(MA) for the domain created.
DUT (config-ether-cfm)#exit Exit the CFM database.
DUT(config)#interface eth-0-9 Specify the interface (eth-0-9)to be
configured and enter the Interface
mode
DUT(config-if)# switchport mode trunk Set the switching characteristics of
this interface to trunk mode.
DUT(config-if)# switchport trunk allowed vlan all Enable all VLAN IDs on this port.
DUT (config-if)#ethernet cfm mep level 5 down mpid 66 vlan 30 Configure a maintenance end point
(MEP).
DUT (config-if)# no shutdown Bring up the interface.