CanogaOS Command Reference
45-2
Examples
This example shows how to add a collector with IP address 10.0.0.254 and UDP port 3000.
Switch (config)# sflow collector 10.0.0.254 3000
Related Commands
45.3 sflow counter interval
Use this command to configure sFlow polling-interval for counter sample.
Command Syntax
sflow counter interval <1-2000>
no
sflow counter interval
sflow: Sampled flow
counter: Set sFlow interface counter
interval: Set interface counter interval
<1-2000>: Interval value in second
Command Mode
Global configuration mode
Usage
Use this command to set sFlow polling-interval for counter sample. Use the no parameter with this command
to set a default value. Default interval value is 20 seconds.
Examples
This example shows how to set sFlow polling-interval to 10 second
Switch (config)# sflow counter interval 10
Related Commands
45.4 sflow counter enable
Use this command to enable or disable counter sampling on individual port.
Command Syntax
(no|)
sflow counter
sflow: Set sFlow params
counter: sFlow interface counter
enable: Enable service
Command Mode