9161 Ethernet Network Interface Device User’s Manual Troubleshooting
Fault Conditions
34
Table 4-1. 9161 Management LEDs
Table 4-2. 9161 Interface LEDs
NOTE: The NET LED is non-functional. It is turned ON/OFF manually, and
does not effect the operation of the 9161
4.2.2 Link Loss Forwarding
When Link Loss Forwarding (LLF) is enabled, a fault on one side of the 9161 propagates to the
other side to notify that device and stops signal transmission (see Figure 5-2). Set the LLF prop-
agation to 10G1 to 10G2, 10G2 to 10G1, or both directions. Set this in the User Interface at the
Functional Configuration screen (reference Chapter 3).
LED Status Description
P1 (Primary) or
P2 (Secondary) Power
Off No power/power supply not installed
Green Normal operation
Amber System self-test
Red Power failure/Major alarm
Fans
Green Normal operation
Amber System self-test/one fan failed
Red More than one fan failed
Red blinking Fan not installed
Management
Off No power
Green Normal operation
Green blinking Management traffic
Amber System self-test/over-temperature
Amber blinking Management traffic with over-temperature
Red Diagnostic or CPU failure
LED Status Description
TX
Off No transmission activity
Green blinking Transmission activity
Amber System self-test
Red
Port disabled; may be due to Link Loss For-
warding (LLF)
RX
Off No link
Green Link established
Green blinking Receiving activity
Amber System self-test
Red Receiving Remote Fault
NET
Off Non-network connection
Green Network connection
Amber System self-test